Plunger Type 7.0 MPa
High Pressure Unit
- Turbulence™ Filter
-
Special turbulence cleans the filter automatically, rendering the filter clog free.
- Plunger Pump/7.0 MPa–3.0 MPa
-
Piston action pushes fluid at high to medium pressure.
FEATURES
YTH-EP
An All-in-one, High-to-medium Pressure Coolant Unit
All components of a coolant system are consolidated into a single pump. No inline and suction filters are required. The saved space expands the available plant space, resulting in a higher production efficiency.
- Maximum operating pressure: 7.0 MPa.
- Maximum flow rate: 28.8 liters/min.
- No suction filter is required.
- No inline filter is required.
- No plumbing is required to interconnect various components.
Turbulence™ Filter
Our special Turbulence™ design generates turbulence around the surface of filter with 2 wing-shaped vanes rotating around filter and can wash away sludge from filter surface continuously.
High Efficiency Plunger Pump
- Compatible fluid type
- Water soluble coolant (Please consult us if you use non-water soluble coolant).
- Incompatible with lubricant oils, fuel oils.
- Incompatible with clear water, demineralized water, aqueous solutions and viscous fluids without rust-preventive property, corrosive fluids, solvents, and any cutting fluids that contain active sulfur.
- Relief valve is built into the pump.
Filter Rating (Nominal value)
Suction strainer | 3 mm (Solids larger than this must be removed from the tank.) |
Filter | 20 µm, 50 µm |
Corresponding Chip Type
MODEL NUMBERING SYSTEM
YTH-EP
MODEL NUMBERING SYSTEM
TOP−YTH ① ② – ③ E VD ④ ⑤
①Motor Capacity | 2200: 2.2 kW 3700 : 3.7 kW |
②Motor Type*1 | [Standard Motor] A3: AC 200/200/220/230 V 50/60/60/60 Hz 3 phase electric induction motor (IE3) with CE marking [Local Motor] AE: supplied by NOP Germany AF: supplied by NOP Taiwan AJ: supplied by NOP Asia (China) AK: supplied by NOP India AU/AV: supplied by NOP North America (USA) |
③Pump Capacity (Plunger pump) | P008: 8 cc / rev P010: 10 cc / rev P014: 14 cc / rev P016: 16 cc / rev |
E: Filtering Method | Turbulence™ filter |
VD: Relief Valve | External return type |
④Relief Pressure Setting*2 | 70: 7.0 MPa 60: 6.0 MPa 35: 3.5 MPa 30: 3.0 MPa |
➄Filter Rating | B: 50 μm*3 C: 20 μm*4 |
*2 See “Specifications” to select a model that satisfies your desired relief valve set pressure.
*3 Please consult us if you use non-water soluble coolant as they can only be used in limited conditions.
*4 20 μm filter can not be applied to non-water soluble coolant.
SPECIFICATIONS
Model | Motor Capacity (kW) | Flow Rate (L/min) 50 Hz/60 Hz | Maximum Pressure (MPa) 50 Hz/60 Hz | Approximate Weight (kg) |
YTH2200A3-P008EVD70* | 2.2 | 12.0/14.4 | 7.0/7.0 | 53 |
YTH2200A3-P010EVD** | 2.2 | 15.0/18.0 | 7.0/6.0 | 53 |
YTH2200A3-P016EVD** | 2.2 | 24.0/28.8 | 3.5/3.0 | 53 |
YTH3700A3-P014EVD70* | 3.7 | 21.0/25.2 | 7.0/7.0 | 62 |
YTH3700A3-P016EVD** | 3.7 | 24.0/28.8 | 7.0/6.0 | 62 |
DIMENSIONS
YTH-EP
Typical/Motor Type: A3
形式 | L | H | M | φD | θ(°) | TB |
YTH2200A3-P008EVD70* | 753.3 | 433 | 311 | 202 | 45 | 168 |
YTH2200A3-P010EVD** | 753.3 | 433 | 311 | 202 | 45 | 168 |
YTH2200A3-P016EVD** | 753.3 | 433 | 311 | 202 | 45 | 168 |
YTH3700A3-P014EVD70* | 768.3 | 448 | 326 | 243 | 45 | 187 |
YTH3700A3-P016EVD** | 768.3 | 447 | 326 | 243 | 45 | 187 |
SAMPLE SYSTEM LAYOUT
YTH-EP
Please be sure to read the instruction manual before use.
PERFORMANCE CURVES
YTH-EP
YTH-EP LINE TYPE
*The model number of Line type ends with capital letter “L.” The pump specification is the same as YTH-EP.
NOP Filter Pump External Type
Unlike normal type that can only be installed upon a coolant tank, this external type can be installed independently in a distant place with an extension pipe.
Alteration of tank cover is no longer necessary, allowing quick and easy retrofitting.